SSD 690+ AC Frequency Inverter for 11kW (15HP) 220V 3 Ph motor to 42A at high overload or 15kW (20HP) to 54A when Fan/Pump rated, operates in VxF, Sensorless Flux Vector or Full Closed Loop Flux Vector control (when the optional encoder board is fitted). Simple set-up and ready to run in VxF from its default settings.
Size D - 252mm Wide x 245mm Deep x 471mm High overall.
Overload - 150% x 60 seconds and 180% for 0.5seconds.
Speed Control Range - 0/300Hz (switching frequency is 3kHz).
Braking - 100% x 20 seconds duty or 30% continuous into minimum 14 Ohm external resistor. See the Resistor options linked below or use the 'Which Resistor' button on this page.
4 x Analogue Inputs, 8 Digital Inputs, 3 Analogue outputs, 3 Digital outputs (relay contacts).
Input Current - 45A at high overload or 54A when Fan/Pump rating set.
Input Voltage - 380/460V three phase +-10% at 50/60Hz.
Input fuse - 50A at high overload and 63A when Fan/Pump rating set - to suit input bridge at 6000A²s
Cubicle mount.
Rated at 40C Ambient.
Ventilation space above and below - 70mm.
Ventilation space at sides - 25mm.
Heat Loss at max output - 640W at high overload or 820W when Fan/Pump rating set.
Mounting - M6 screw fixings on 150mm x 440mm centres.
Full part number is - 690-232420D0-B00P00-A400. Was - 690PD-0110-220-0011-UK-0-0-0-0-B0-0-0. - Exactly the same as SSD Drives and Eurotherm Drives - 690PD-0110-220-0010-UK-0-0-0-0-B0-0-0.
The menu uses simple to understand English-language terms to describe its selection and functions. The default is English, but can be changed to German, French, Spanish, Italian, Polish, Swedish and Portuguese, by going to 'System', then 'Languages' and selecting the language required.
Replaces:- 620STD/0110/220/0010/UK/ENW/0000/000/B0/000/000, 620COM/0110/220/0010/UK/ENW/0000/000/B0/000/000, 620ADV/0110/220/0010/UK/ENW/0000/000/B0/000/000, 584SV/0110/220/0011/UK/000/0000/B0/000/000,