Parker 710 Power Module for a fixed frequency 400V 3 phase AC supply. Rated at 5.5kW, 12A when in high overload or 7.5kW, 15A, when in fan/pump mode. Capable of controlling an asynchronous AC motor in open loop V/f, open loop vector, or closed loop vector when the encoder module is fitted. Can also control brushless AC ‘pmac’ motors in open loop vector mode or closed loop vector and position mode when the resolver module is fitted.
POWER MODULE ONLY: Use a compatible AC30 control module for STO function.
Frame Size: E. Dimensions: (HxWxD mm) 333x125x255.
Weight: 6.8kg
5.5kW, 12A at 150% overload for 60 seconds.
7.5kW, 15A at 110% overload for 60 seconds.
Dynamic Braking: minimum resistance, 71 ohms.
EMC compliance: None.
Standard 3C3 coated pcb’s.
Input voltage: 380-480±10%, 50/60Hz, ±5%.
Input current: 10.6A in heavy duty or 14.5A in normal duty.
Wall mount in clean environment or cubicle mount.
Rated at 40°C ambient.
Ventilation space in front: 10mm.
Ventilation above and below: 75mm.
Ventilation at the sides: 0mm.
Mount 4 x 4.5mm diameter M4 screws, 320x100mm apart.
Heat loss: 225W.
Manufacturer part number: 710-4E0016-BN-0S-0000.
Download Parker AC30 installation and software manuals from the link below: